Constant temperature mixed water valve
Thermostatic Mixing Valve
Working principle
A heat sensor is installed at the water-outlet of the constant temperature mixed water valve, the valve core in the valve body is moved by the temperature sensor to block or open the cold, hot water-inlet. The hot water opening is increased while the cold water opening is decreased, when the temperature adjusting knob sets a certain temperature, the cold, hot water ratio at the water-outlet will be changed as well regardless of the change of the cold water-in or hot-water in temperature, therefore, the constant water-out temperature is ensured.
Thermostatic Mixing Valve
Working principle
A heat sensor is installed at the water-outlet of the constant temperature mixed water valve, the valve core in the valve body is moved by the temperature sensor to block or open the cold, hot water-inlet. The hot water opening is increased while the cold water opening is decreased, when the temperature adjusting knob sets a certain temperature, the cold, hot water ratio at the water-outlet will be changed as well regardless of the change of the cold water-in or hot-water in temperature, therefore, the constant water-out temperature is ensured.
Max. working pressure: | 1Mpa |
Ideal working pressure: | 0.1-0.6Mpa |
Hot water temperature: | 50~80ºC |
Max. water temperature: | 100 ºC |
Adjusting scope: | 30-55ºC\35-65ºC |
Temperature control accuracy: | ±2ºC |
Cold\hot water-in pressure differential: | 8:1 |
Through-diameter | G1/2"\G3/4" |
Flow: | 1m3/h~20m3/h |
Product standard: | Q/BXJ02.03-2003 |